Automatic constant pressure valve + electric control valve performance

March 05, 2023
Abstract: Automatic constant pressure differential valve + electric control valve is used to solve the balance of air conditioning water system is a very good way, when the system pressure changes, the constant pressure differential valve can change its own flow area so that the electric control valve The pressure difference between the two ends remains the same, so that the CV value of the control valve is always one, thus ensuring that the electric control valve has been running in the best conditions, the real change in water temperature and has nothing to do with the pressure can be guaranteed The volume of water entering the air conditioner box is the amount of water you need at any one time. Plexus makes the system more superior performance, more convenient to maintain. Automatic constant pressure differential valve electric control valve hydraulic balance I. Automatic constant pressure differential valve + electric control valve performance profile Automatic constant pressure differential valve + electric control valve is currently used to solve the air conditioning water system balance a very good way, When the system pressure changes, the constant pressure differential valve can change its own through-flow area so that the pressure across the electric control valve remains the same, so that the CV value of the control valve is always one, so as to ensure that the electric control valve has been the most The ideal operating conditions, the real change is only the temperature and the water has nothing to do with the pressure, to ensure that the amount of water into the air conditioning box at any time is the amount of water you need. Plexus makes the system more superior performance, more convenient to maintain. The use of an automatic constant pressure differential valve + electric control valve at the end of the system eliminates the need for extensive use of balancing valves in stratified control so that system performance is superior and maintenance is more convenient. Automatic constant pressure differential valve + electric control valve is a variable flow air conditioning water system, an important guarantee of hydraulic balance, the use of automatic balance proportional integral valve in the system can bring you many benefits. 1, Because does not need to carry on the system debugging, therefore saves a lot of troubles, saved a large amount of time, shortened the completion date; 2, because does not need to use the valve group and the valve which is used for the stratification control, therefore has saved you more tubing , Insulation materials and installation costs and time; 3, so that the water system at all times in a balanced state, so regardless of the installation of staged construction or equipment will not affect the use of water system balance; 4, even after the project or put into operation Changing some uses and changing the water system design in some areas will not affect the design of water systems in other areas and will not affect the water system balance in other areas. 5. Because the whole system is in a state of dynamic equilibrium, the refrigeration units And the pump will be the most energy-efficient operation, saving a lot of operation and maintenance costs; 6, due to the system flow balance is automatic, make installation and maintenance more convenient and eliminate the possibility of human operation failure to destroy the balance. Second, the automatic balance proportional integral control valve and the static balance valve comparison Static balance valve is actually a man-made precise set of opening valve, he adjusted by the local resistance to air conditioning water piping system to solve part of the hydraulic balance questionable. At the beginning of the system commissioning, all the valves of the system are at a certain opening. The commissioning personnel set the opening of each static balance valve one by one according to the original mathematical model (the valve opening is set to a certain value after setting) , But for different water systems its resistance distribution curve is definitely not the same, and it can not be measured. Therefore, the static balance valve can only fuzzy, qualitative control of water flow. For a variable flow air conditioning water system, each air conditioning tank of water changes are random, the entire pipeline pressure changes are unpredictable, the valve opening is also random changes. Therefore, we can get from the formula G (flow) = CV × A (valve flow area) × △ P (differential pressure across the valve): Since the static balance valve is adjusted, the opening degree is a certain value. Therefore, changes in the pressure differential across the valve will inevitably result in changes in the flow through the static balance valve. So in a variable flow system when the system pressure changes when the static balance valve is unable to solve the problem of hydraulic imbalance. Will still cause the system over-current and under-current.
Liên hệ chúng tôi

Author:

Ms. Lucia Peng

Phone/WhatsApp:

+8613531888018

Sản phẩm được ưa thích
You may also like
Related Categories

Gửi email cho nhà cung cấp này

Chủ đề:
Thư điện tử:
Tin nhắn:

Your message must be betwwen 20-8000 characters

We will contact you immediately

Fill in more information so that we can get in touch with you faster

Privacy statement: Your privacy is very important to Us. Our company promises not to disclose your personal information to any external company with out your explicit permission.

Gửi